FOTEK — User manual

The damping valve is a component of the delivery valve and its construction is shown in Fig. 17. Delivery valve holder Damping valve spring Orifice The damping valve compresses the damping valve spring and opens almost simultaneously with the opening of the delivery valve. Fuel oil delivered by the plunger through the injection pipe is then delivered to the nozzle holder and the nozzle. After the end-of-injection the damping valve is closed more quickly (seated) than the delivery valve by the set force of the damping valve spring.

Damping valve Following this, because only the retracted fuel oil is returned through the small orifice in the Delivery valve spring centre of the damping valve up until the time that the delivery valve is seated, a sudden re- Delivery valve can be prevented. duction in the injection pipe’s in-line pressure A sudden reduction oe in pressure may some- times result in negative pressure, thereby causing cavitation. This may result in corrosion of the injection pipes and finally the danger of pipe breakage. The damping valve is installed to prevent the above problems. Fig. 17 Damping valve operation 14 .-