. OPERATION COLD WEATHER OPERATION BATTERY WARNING AFTER COMPLETION OF WORK The undercarriage, belt conveyor and feeder may be frozen due to mud and water on them, hindering the engine from starting up the next morning. To prevent such a trouble, observe the following. Remove the mud and water on the machine. Park the machine on the hard and dry ground. If a ground of such conditions is not available, place wooden boards on the ground and park the machine on them. That practice will prevent the undercarriage from being frozen, keeping it off the ground, and the machine can normally be started the next morning.
Open the drain valve and drain any water collected in the fuel system to prevent it from freezing. As the battery capacity drastically drops in low temperatures, cover or remove the battery from the machine, store the battery in a warm place, and install it again the next morning. If the electrolyte level is low, add distilled water in the morning before beginning work. Do not add water after the day's work to prevent diluted electrolyte in the battery from freezing during the night. The machine can be protected from fast cooling down during the night time either by parking it in a garage or covering it with tarpaulin.
Disconnect the hose from the water sprinkler nozzle or drain all water in it. AFTER COLD WEATHER When the season changes and the weather becomes warmer, do as follows. Replace the oil in each component and fuel with those of the designated viscosity, following the instructions set forth in "USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE (PAGE 4-14)". 3 - 108 To avo id gas explosions, do not brin g fire o r sparks nea r the battery. Batter y electrolyte is dangerous. If it gets in your eyes o r on your skin, wash i t off with large amounts of water, and consult a doctor . When th e ambient temperature drops, the capacity o f the battery will also drop.
I f the battery charge ratio is low, the battery e lectrolyte may freeze. Maintain t he battery charge a s close as possibl to 100%. Insulate cold temperature to ensure the machine can b e started e asily the next morning. REMARK Measure the specific gravity and calculat e the charging r ate from the following conversion table Electrolyte Temperature (°C) Charging Rate (%) 20 0 -10 -20 100 1.28 1.29 1.30 1.31 90 1.26 1.27 1.28 1.29 80 1.24 1.25 1.26 1.27 75 1.23 1.24 1.25 1.26