eng — OTHER TROUBLE

. OPERATION TROUBLESHOOTING ELECTRONIC CONTROL SYSTEM AND RELATED ACCESSORIES Monitor Display Failure Mode Corrective Action E02 Error in TVC valve system Turn pump redundancy switch on and normal work can be started. But have machine inspected promptly. (*) E05 Error in speed governor system Governor controller is incapacitated. Operate governor manually. For fixing at full speed, fixing bolt hole is provided on the bracket. In this case, have governor inspected promptly. CALL Error disabling work to continue Set machine in safe posture and receive inspection promptly. Unable to operate the work equipment or turn the machine without display of an error code Ask for inspection promptly.

(*)For how to use the emergency pump starting switch, see the section of "SWITCHES (PAGE 3-16)" FAILURE DISPLAY BY LX CONTROLLER If an error code is shown in the display of any work equipment controller, contact the Komatsu distributor in your territory, informing the error code and asking for a prompt inspection. LX controller error codes The LX controller indicates an error code with two led, when something unusual takes place. When it is turned on, the following didplay appears on the screen. 3 - 121