SYSTEM / Electrical System Starter Relay 2 Operation 1. When the key switch is turned to the START position, key switch terminal B is connected to terminal ST. Current is routed to the base in transistor (Q2) through resistance R4 in starter relay 2. Then, transistor (Q2) is turned ON and current flows to coil (L) in starter relay 2. Therefore, starter terminal B is connected to terminal C and the starter is operated. 2. After the engine starts, the alternator starts generating electricity and voltage at starter relay 2 terminal R increases. 3. When this voltage increases up to 21 to 22 V, Zener diode (Z) is turned ON. Consequently, transistor (Q1) is turned ON.

Then, current to the base of transistor (Q2) does not flow and transistor (Q2) is turned OFF. At this moment, starter terminal B is disconnected from terminal C and the starter is turned OFF. NOTE: Condenser C1 is used to stabilize the operating voltage. Diode D4 protects the circuit in case the battery terminals are reversely connected. Starter Relay 2 S B (1) D 3 L R 3 R 4 (2) C From Alternator Terminal L R R 2 Z D 2 Q 2 (1) C M (2) Q 1 B E D 4 C 1 C Starter BST 12V Key Switch 12V Battery T107-04-04-003 T2-5-10