TROUBLESHOOTING/ Monitor Unit Auto-Idle Display(1) When selecting auto-idle from the switch panel, the monitor unit displays auto-idle display (1). When the key is turned ON with auto-idle switch ON position, auto-idle display (1) blinks for 10 seconds. 2 1 3 4 Overload Alarm Display (2) (Optional) 5 T1V1-05-02-002 The MC measures the load of suspended load from the bottom pressure sensor of boom cylinder. When overload is detected according to the signal from MC through CAN, an alarm is displayed. (Refer to T5-2-10.) Auto-Lubrication Display (3) When auto-idle switch is turned ON, auto-idle dis- play (3) is displayed according to the signal from MC through CAN.
M1J1-01-003 Glow Display (4) While ECM is supplying current to the glow plug, the date is displayed according to the signal from ECM. Fuel Consumption Gauge Display (5) Fuel consumption is displayed according to the sig- nal from ECM, which is received through MC by us- ing CAN. T5-2-3