TROUBLESHOOTING/ Monitor Unit Overload Alarm (Only machines equipped with optional parts) Alarm IMPORTANT: When using overload alarm, make overload alarm available by using Dr. ZX. MC measures load of the suspended load from bot- tom pressure sensor of the boom cylinder. An alarm message is displayed and a buzzer is rung, if over- load is detected according to the signal from MC through CAN. 1. If overload of the suspended load is dissolved, the alarm message disappears and the buzzer stops ringing. M1J1-01-016 Primary Screen NOTE:
Even if the work is done while displaying a screen except the primary screen, when an overload condition is reached, the screen of monitor unit is switched to the primary screen, an alarm message is displayed, and a buzzer is rung. Even after the overload alarm is dissolved, the monitor unit keeps on displaying the primary screen without returning to the screen while the work is done. Overload Alarm ON/OFF Switch (Optional) T1V1-05-02-004 T5-2-10