hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING/ Monitor Unit 3. If inputting an incorrect password three times, a screen appears informing that the security lock has been applied, and a buzzer rings for thirty seconds. During that time, the buzzer does not stop ringing even if turning of the key switch ON/OFF. 4. After thirty seconds, if the key switch is turned to the ON position, the starting screen appears and the password input screen appears again. Then a password can be input again. If inputting an in- correct password even once this time, the security lock screen appears again and a buzzer rings for thirty seconds. The buzzer does not stop ringing for thirty seconds even if turning the key switch ON/OFF.

T1V5-05-01-005 Security Lock Screen 5. After the buzzer stops ringing, a password can be input again. Turn the key switch to the ON position and input a password after the password input screen appears. (Refer to T5-2-11). T1V1-05-01-115 Starting Screen 6. If inputting an incorrect password again, the secu- rity lock screen appears again. The buzzer does not stop ringing for thirty seconds even if turning the key switch ON/OFF. Password Input Screen T1V5-05-01-093 T5-2-15