hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Dr. ZX Self-Diagnosis Push Fault of ICF Controller. In case of no faulty, No Fault is dis- played. After starting Dr. ZX, push Self-Diagnostic Result. To the lower T1V7-05-03-001 Function Selection Screen Controller Self- Diagnosis Screen T1V7-05-03-008 T1V7-05-03-002 By changing the page, the forward and backward fault code is displayed. Push Details, and Details of the fault code and Corrective Action are displayed. Push ESC and Retry B is dis- played. Push Retry B and return to Controller Self-Diagnosis Screen after executing Retry B. Push ESC and return to Controller Self-Diagnosis Screen directly. Push ESC and Retry B Screen is displayed.

Trouble Retry B ESC ESC T1V7-05-03-003 T1V7-05-03-005 T1V7-05-03-007 If the message of Details is long, push the arrow and change the screen. Retry B Screen Retry B ESC T1V7-05-03-002 Controller Self- Diagnosis Screen T5-3-5