TROUBLESHOOTING / Dr. ZX ADJUSTMENT DATA LIST NOTE: 1 MPa=10.197 kgf/cm 2 1 kgf/cm 2 =0.098 MPa * ML specification is only available in Japanese domestic market. T5-3-20 Adjustment Data Min.
Adjustment Value Adjustable Range Standard Adjustment Remarks Range Li Speed Adjustment 10 min-1 0~150 min-1 0 min-1 WU Speed Adjustment 10 min-1 0~150 min-1 0 min-1 AI Speed Adjustment 10 min-1 -180~500 min-1 0 min-1 E Speed Adjustment 10 min-1 -200~200 min-1 0 min--1 P Speed Adjustment 10 min-1 -200~100 min-1 0 min-1 HP Speed Adjustment 10 min-1 -200~0 min-1 0 min-1 PQ Torque Control 10 N⋅m -1000~160 N⋅m 0 N⋅m Pump 1 Torque Adjustment 10 N⋅m -1000~0 N⋅m 0 N⋅m Pump 2 Torque Adjustment 10 N⋅m -1000~0 N⋅m 0 N⋅m ATT Speed Increase Down Waiting Time 40 ms 0~3000 ms 3000 ms ATT Torque Reducing ON/OFF - - OFF ECO Mode ON/OFF - - OFF HP Mode ON/OFF - - ON Engine Burglar Proof ON/OFF - - OFF Pump Burglar Proof ON/OFF - - OFF Load Alarm Min Bottom Pressure 0.1 MPa -10.0~10.0 MPa 0.0 MPa Lubrication Interval Adj.
1 min 11~253 min 50 min Pump 1 Min. Displacement Adj. 2.5 cm3 0.0~140.0 cm3 0.0 cm3 Pump 2 Min. Displacement Adj. 2.5 cm3 0.0~140.0 cm3 0.0 cm3 Pump Cutoff Pressure Adj. 0.1 MPa -10.0~0.0 MPa 0.0 MPa P1 REG. Offset Adj. 0.006 MPa -0.102~0.102 MPa 0.000 MPa P2 REG. Offset Adj. 0.006 MPa -0.102~0.102 MPa 0.000 MPa Boom Flow Control CUR Adj. 5 mA -640~0 mA 0 mA ATT Mode Save ON/OFF - - OFF