TROUBLESHOOTING / Troubleshooting A T5-6-8 Fault Code Trouble Cause Influenced Control 11400-3 Pump 2 Regulator Valve FB High Current Current: Higher than 920mA All Pump Controls 11400-4 Pump 2 Regulator Valve FB Low Current Current: Less than 56 mA All Pump Controls 11402-3 Boom Flow Control Valve FB High Current Current: Higher than 920mA All Pump Controls 11402-4 Boom Flow Control Valve FB Low Current Current: Less than 56 mA All Pump Controls 11404-3 Power Boost P/S Valve FB High Current Current:

Higher than 920mA • Counterweight Removal and Installation Control • Pressure Increase Selection Control When Traveling • Power Digging Control • Auto-Power Lift Control 11404-4 Power Boost P/S Valve FB Low Current Current: Less than 56 mA • Counterweight Removal and Installation Control • Pressure Increase Selection Control When Traveling • Power Digging Control • Auto-Power Lift Control 11405-3 Travel Swash Angle P/S Valve FB High Current Current: Higher than 920mA Travel Motor Swash Angle Se- lection Control 11405-4 Travel Swash Angle P/S Valve FB Low Current Current: Less than 56 mA Travel Motor Swash Angle Se- lection Control 11410-3 Pump 1 Regulator Valve FB High Current Current:

Higher than 920mA • All Pump Controls 11410-4 Pump 1 Regulator Valve FB Low Current Current: Less than 56 mA • All Pump Controls 11412-3 Hyd. Fan P/S Valve FB High Current Current: Higher than 920mA • Fan Pump Flow Rate Control 11412-4 Hyd. Fan P/S Valve FB Low Current Current: Less than 56 mA • Fan Pump Flow Rate Control 11802-3 Boom Bottom Pressure Sensor Circuit High Input Voltage: 4.5 V or higher • Overload Alarm Control 11802-4 Boom Bottom Pressure Sensor Circuit Low Input Voltage: Less than 0.25 V • Overload Alarm Control 11901-3 Hyd. Oil Temp Sensor Circuit High Input Intake air temperature: 21 °C or higher (higher than 20 °C) Voltage:

4.10 V or higher This condition is continued beyond 30 seconds. • Engine Control • Overheat Prevention Control • Fan Pump Flow Rate Control 11901-4 Hyd. Oil Temp Sensor Circuit Low Input Voltage: Less than 0.23 V This condition is continued beyond 30 seconds. • Engine Control • Overheat Prevention Control • Fan Pump Flow Rate Control