TROUBLESHOOTING / Troubleshooting A T5-6-10 Fault Code Trouble Cause Influenced Control 11910-2 Actual Engine Speed Receive Error Faulty Harness - 11911-2 Security Signal receive Error Faulty Harness - 11914-2 Radiator Water Temp Receive Error Faulty Harness • Overheat Prevention Control • Fan Pump Flow Rate Control 11918-2 Work Mode Receive Error Faulty Harness • Work Mode Control • Attachment Mode Control 11920-2 Fuel Flaw Receive Error Faulty Harness - 11976-3 Auxiliary Valve 2 FB High Cur- rent Current: Higher than 920mA - 11976-4 Auxiliary Valve 2 FB Low Cur- rent Current: Less than 56 mA - 11977-3 Auxiliary Valve 1 FB High Cur- rent Current:
Higher than 920mA - 11977-4 Auxiliary Valve 1 FB Low Cur- rent Current: Less than 56 mA - 11980-3 ATT Relief Change Valve FB High Current Current: Higher than 920mA - 11980-4 ATT Relief Change Valve FB Low Current Current: Less than 56 mA - 11981-3 Fan Reverse Valve 2 FB High Current Current: Higher than 920mA - 11981-4 Fan Reverse Valve 2 FB Low Current Current: Less than 56 mA - 11982-3 Fan Reverse Valve 1 FB High Current Current: Higher than 920mA - 11982-4 Fan Reverse Valve 1 FB Low Current Current:
Less than 56 mA - 11983-2 Intake Air Temperature Receive Error Faulty Harness • Fan Pump Flow Rate Control 11984-2 Boost Temperature Receive Error Faulty Harness • Fan Pump Flow Rate Control 11989-3 Boom Mode Control Valve FB High Current Current: Higher than 920mA • Boom Mode Selector Control 11989-4 Boom Mode Control Valve FB Low Current Current: Less than 56 mA • Boom Mode Selector Control