hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A T5-6-18 Fault Code Trouble Cause Influenced Control 11997-3 Bucket Roll-Out Pilot Pressure Sensor Circuit High Input Voltage: 4.75 V or higher • Boom Mode Selector Control • Boom Flow Rate Control Valve Control • Engine Control 11997-4 Bucket Roll-Out Pilot Pressure Sensor Circuit Low Input Voltage: Less than 0.25 V • Boom Mode Selector Control • Boom Flow Rate Control Valve Control • Engine Control 11998-3 Boom Lowering Pilot Pressure Sensor Circuit High Input Voltage: 4.75 V or higher • Boom Mode Selector Control • Boom Flow Rate Control Valve Control • Engine Control 11998-4 Boom Lowering Pilot Pressure Sensor Circuit Low Input Voltage:

Less than 0.25 V • Boom Mode Selector Control • Boom Flow Rate Control Valve Control • Engine Control