hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11003 Fault Code Trouble Cause 11003-3 Abnormal Sensor Voltage Faulty MC IMPORTANT: If fault code 11003-3 (Abnormal sensor voltage) is displayed with other fault codes together, perform the diagnosing for fault code 11003-3 first. YES Faulty sensor Short-circuited harness between MC and sensor in the harness with continuity Disconnect all connectors at MC end. Check for continuity between terminals #1 and #3 of harness end connector of each sensor. YES NO · Key switch:

OFF Connector (Harness end of connector viewed from the open side) Pressure Sensor (Right Travel) Pressure Sensor (Left Travel) Pressure Sensor (Front Attachment) (Optional) Pressure Sensor (Swing) Pressure Sensor (Boom Raise) Pressure Sensor (Boom Lower) Pressure Sensor (Arm Roll-In) Pressure Sensor (Arm Roll-Out) Pressure Sensor (Bucket Roll-In) Pressure Sensor (Bucket Roll-Out) Pressure Sensor (Counterweight) (Optional) Pressure Sensor (Auxiliary) (Optional) Pump 1 Control Pressure Sensor Pump 2 Control Pressure Sensor Pump 1 Delivery Pressure Sensor:

Pump 2 Delivery Pressure Sensor T1J1-05-06-002 T1J1-05-06-001 T5-6-41 Disconnect connectors of all sensors corresponding to the displayed fault code and retry. Check if fault code 11003-3 disappears. Faulty MC NO