TROUBLESHOOTING / Troubleshooting A PILOT FAILURE MC FAULT CODE 11992 Faulty harness between MC and pump 2 regulator pressure sensor. Check if harnes between terminal #D4 of harness end of connector MC-D in MC and terminal #2 in pump 2 regulator pressure sensor is open or shorted. YES YES Faulty MC. Disconnect connector of pump 2 regulator pressure sensor. Check fi voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. NO NO Open circuit in harness between MC and pump 2 regulator pressure sensor (terminal #3). Switch pump 1 regulator pressure sensor with pump 2 regulator pressure sensor and retry. Check if fault code disappears.
Check fi voltage between terminal #1 of harness end of connector in pump 2 regulator pressure sensor and machine is specification. YES · Key switch: ON NO NO Open circuit in harness between MC and pump 2 regulator pressure sensor (terminal #1). · Key switch: ON · Refer to the table upward. Faulty pump 2 regulator pressure sensor. YES Connector (Harness end of connector viewed from the open side) MC Connector MC-D Pilot Pressure Sensor (Pump 2 Regulator) #D4 T1J1-05-06-001 T183-05-04-009 T5-6-86 Fault Code Trouble Cause 11992-3 Abnormal Pump 2 Regulator Pressure Sensor High Voltage Voltage: 4.75 V or higher 11992-4 Abnormal Pump 2 Regulator Pressure Sensor Low Voltage Voltage:
Less than 0.25 V