TROUBLESHOOTING / Troubleshooting B E-2 Even if starter rotates, engine does not start. Check the wiring connections first. Connect terminal #1 of harness end of connector in ECM main relay to ma- chine. Check for continuity between terminals #21 and #40 of har- ness end of connec- tor in ECM. Disconnect ECM main relay from connector. Check if voltage at ter- minal #3 of harness end of connector is 24V. YES Switch ECM main relay with other gen- eral relay. Check if engine starts. Connect terminal #5 of harness end of connec- tor in ECM main relay to machine. Disconnect connector in ECM. Check for continuity between terminals #2 and #5 of harness end of connector.
YES Open circuit in harness between ECM main relay and ECM. NO NO NO Connector (Harness end of connector viewed from the open side) ECM Main Relay Connector ECM #21 #24 #5 T183-05-04-003 T1GR-05-04-002 #40 #2 T5-7-38 YES Faulty ECM main relay. Open circuit in harness between key switch and ECM main relay. · Check if fuse #8 is blown.