TROUBLESHOOTING / Troubleshooting B A-9 Flow rate of pump2 is not reduced to speci- fication when operating attachment. Reference Page T5-6-28 T5-6-55 T5-6-63, 64 MC T5-6-69 Although the attachment is operated with work mode in digging, pump 2 flow rate remains kept minimum. Check the wiring connections first. T5-7-61 Trouble 11004 CAN Communication Error 11400 Abnormal Pump 2 Control Solenoid Valve 11918 Work Mode Receive Error 11992 Abnormal Pump 2 Regulator Pressure Sensor YES Refer to Troubleshoot- ing A. Check if fault code is displayed. YES Faulty monitor unit. Check if swing speed is within specification. NO · Refer to Operational Faulty MC. Performance Test.
NO Refer to Troubleshoot- ing A. Faulty MC. NO