TROUBLESHOOTING / Troubleshooting B SWING SYSTEM TROUBLESHOOTING S-1 Swing is slow or unmoving. Check whether the pilot system is faulty or the main circuit is faulty. In case other functions (front attachment and travel) operate normally, the pilot pump is con- sidered to be normal. If the pilot system is dis- playing a problem, the cause of trouble may exist in the circuit after the pilot valve. In case the left travel speed is also slow, refer to A-2. Signal Control Valve (Pilot Valve Side) Port SH T1J1-05-07-005 T5-7-74 Check if swing motor Install a pressure gauge to YES parking brake release port SH. Measure parking valve is bound or brake release pressure. scored.
YES Check if pressure is be- tween 3.4 to 4.9 MPa (35 to 50 kgf/cm2, 495 to 710 psi). Faulty swing parking brake Monitor secondary release valve spool in sig- pilot pressure. · Arm relief operation NO nal control valve. Check if secondary pilot pressure is normal. Specification: Refer to NO Faulty pilot valve. Operational Perform- ance Test. Disassemble and clean Monitor item: Swing pilot valve. control pilot pressure NO Check if trouble occurs. Possible to display by Faulty swing shuttle valve. using built-in diagnosing YES Check if swing motor parking brake release valve is bound or scored. Faulty swing shuttle valve. YES