hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B O-2 Counterweight removal/installation device is not operated or power is weak. Reference Page T5-6-57 Refer to the page for Pump Control for Counter- weight Removal and Installation in Control Sys- tem group/ SYSTEM in T/M (Operational Princi- ple). If other actuator is not operated or slow, the pilot system may be faulty. Refer to A-1. If power is weak, refer to F-1 and F-2. Check the wiring connections first. Faulty pressure sensor (counterweight). Open circuit in harness between terminal #1 of connector of pressure sensor (counterweight) and MC, or faulty MC. NO Monitor secondary pilot pressure. Check if secondary pilot pressure is nor- mal.

· Monitor item: Coun- terweight re- moval/installation control pressure · Counterweight re- moval/installation op- eration · Key switch: ON Refer to F-1 and F-2. MC Connector MC-D Pilot Pressure Sensor (Counterweight) #D3 T1J1-05-06-001 T183-05-04-009 T5-7-84 Trouble 11404 Abnormal Solenoid Valve unit (SG) Switch pressure sen- sor (counterweight) NO with other pressure YES NO YES Disconnect connector of pressure sensor (coun- terweight). NO Check if voltage at ter- minal #1 of harness end of connector is 5±0.5 V. Disconnect connector D in MC. Connect terminal #3 of connector D to ma- chine.

Check for continuity YES between terminal #2 of harness end of con- nector of pressure sensor (counterweight) and machine.