TROUBLESHOOTING / Troubleshooting B O-3 Counterweight removal/installation speed is fast. Precise operation cannot be per- formed. Refer to the page for Pump Control for Counter- weight Removal and Installation in Control Sys- tem group / SYSTEM in T/M (Operational Princi- ple). When operating counterweight removal / installa- tion, flow rates of pumps 1 and 2 are minimum. Therefore, if other actuator speed is fast, the pump control may be faulty. Refer to A-6. Check the wiring connections first. Faulty pressure sen- sor (counterweight). Open circuit in har- ness between terminal #1 of connector of pressure sensor (counterweight) and MC, or faulty pilot valve.
Monitor secondary pilot pressure. Check if secondary pilot pressure is nor- mal. · Monitor item: Coun- terweight re- moval/installation control pressure · Counterweight re- moval/installation op- eration Faulty MC.
Connector (Harness end of connector viewed from the open side) Pilot Pressure Sensor (Counterweight) T1J1-05-06-001 T5-7-86 Related Fault Code Trouble Reference Page MC 11200 Abnormal Pump 1 Delivery Pressure Sensor T5-6-50 11202 Abnormal Pump 2 Delivery Pressure Sensor T5-6-51 11400 Abnormal Pump 2 Control Solenoid Valve T5-6-55 11410 Abnormal Pump 1 Control Solenoid Valve T5-6-59 11992 Abnormal Pump 2 Regulator Pressure Sensor T5-6-69 11994 Abnormal Pump 1 Regulator Pressure Sensor T5-6-71 Switch pressure sen- sor (counterweight) NO with other pressure YES NO YES