hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B O-4 Auto lubrication is faulty. Even if the auto lubrication switch is turned ON, auto lubrication is not operated. Check the wiring connections first. Interval: 90 minutes (The interval setting can be changed between 10 and 90 minutes.), Lubricat- ing time: 5 minutes Monitor lubrication pump status. YES · Monitor item: Auto lu- brication switch · Auto lubrication switch: ON Switch auto lubrication relay (R11) with other general relay. Check if symptom is improved. · Monitor item: Lubrica- tion mode · Auto lubrication switch: ON NO Disconnect auto lubri- cation switch and connector MC-B in MC.

Check for continuity between terminal #9 of harness end of con- nector in auto lubrica- tion switch and termi- nal #B3 of harness end of connector in MC. YES Faulty auto lubrication switch. NO Open circuit in har- ness between auto lubrication switch and MC. NO Connector (Harness end of connector viewed from the open side) Auto Lubrication Switch MC Connector B B1 #B3 B8 T1J1-05-07-003 #9 B19 B25 T5-7-88 YES Monitor auto lubrica- tion proximity switch. Check if ON/OFF is YES No grease, or dam- aged lubrication pipe. YES switched and dis- played alternately during monitoring. Check if “Lubrication” is displayed. · Monitor item:

Lubrica- tion pump status Monitor auto lubrica- tion device switch. Check if “auto” is dis- played. YES Faulty auto lubrication relay (R11). NO