TROUBLESHOOTING / Troubleshooting B Cooling Circuit Refrigerant pressure in both high and low-pressure sides is low. Bubbles can be seen in sight glass. Piping and/or parts are stained with oil, respond to gas detector. No oil stain is found or gas detector does not respond. Refrigerant has not been refilled for longer than one sea- son. No bubbles are seen in sight glass. After cooling at fast speed continu- ously, cooling power is reduced. Air flow volume remains unchanged. Air flow volume is reduced. Insuffi- cient Cooling Power Refrigerant pressure in low-pressure side is high. Bubbles can be seen in sight glass. Compressor cylinder is extremely hot, emitting a smell.
Refrigerant pressure in high-pressure side is low. Compressor cylinder is extremely hot, emitting a smell. Heater unit emits hot air. Refrigerant pressure in high-pressure side is high. Bubbles can be seen in sight glass. Refrigerant pressure in low-pressure side is low. Condenser is stained and clogged. Even if condenser is sprayed with water, few bubbles appear. Receiver dryer tem- perature is low. Frost forms. After cooling at fast speed continu- ously, cooling power is reduced. Air flow volume is reduced. Thermistor does not cool. Thermistor cools. T5-4-98