hitachi — PREPARATION FOR PERFORMANCE TESTS

OPERATIONAL PERFORMANCE TEST / Standard DR. ZX MONITOR INDICATING VALUES (MC) Unless specified, test under the following conditions. Engine Speed: Fast Idle Work Mode Switch: Digging Mode Power Mode Switch: P mode Auto-Idle Selector: OFF Hydraulic Oil Temperature: 50±5°C NOTE: Items marked ( ) are measurable with the built-in diagnosing system. Items marked ( ) are measurable with the built-in diagnosing system. However, it may be difficult to read the measured value while operating the machine.

T4-2-8 Item Reference Value Measured Value Remarks First Second Third Average TARGET ENGINE SPEED (min-1) ∗ Fast Idle (HP Mode) Fast Idle (When operating a control ∗ lever) ∗ Fast Idle (HP Mode) ∗ Fast Idle (E Mode) ∗ Auto-Idle ∗ Slow Idle 1600 1700 1800 1580 1030 750 When Boom Rise Relieving ACTUAL ENGINE SPEED (min-1) ∗ Fast Idle Fast Idle (When operating a control ∗ lever) ∗ Fast Idle (HP Mode) ∗ Fast Idle (E Mode) ∗ Auto-Idle ∗ Slow Idle 1650 1750 1850 1630 1180 900 When Boom Rise Relieving ENGINE SPEED DEVIATION (min-1) ∗ Fast Idle Fast Idle (When operating a control ∗ lever) ∗ Fast Idle (HP Mode) ∗ Fast Idle (E Mode) ∗ Auto-Idle ∗ Slow Idle 50 50 50 50 150 150 EC DIAL ANGLE (Volt) ∗ Minimum ∗ Maximum 6.58 4.42