hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B 8. Confirm that the high pressure and low pressure valves in the gauge manifold and the refrigerant container valve are closed. Start the engine and operate the air conditioner. Operating Conditions of the Air Conditioner: Engine Speed : Slow Idle Cab Window : Fully Open Cooler Switch : ON Airflow Volume : Maximum Thermo Switch : Maximum IMPORTANT: Do not open the high pressure valve in the gauge manifold. 9. Open the low pressure valve in the gauge manifold and the refrigerant container valve to charge with refrigerant until the bubbles seen in the receiver/drier sight glass disappear. Open NOTE:

The required refrigerant quantity is 1150 g ± 50 g (2.53 ± 0.01 lb). 10. If the refrigerant container becomes empty during the charging work, replace it with a new refrigerant container as follows: Close the high pressure and low pressure valves on the manifold gauge. Replace the empty container with a new one. Tighten, then slightly loosen the refrigerant container joint. Slightly open the low pressure valve on the manifold gauge. When the refrigerant container joint starts to leak, immediately tighten the refrigerant container joint and close the low pressure valve on the manifold gauge. 11.

After charging, close the low pressure valve in the gauge manifold and the refrigerant container valve. Stop the engine. Open W115-02-10-007 Close Close W115-02-10-007 T5-7-111