TROUBLESHOOTING / Troubleshooting B Warm-up Operation After charting the air conditioner, carry out warm-up operation five minute to lubricate system with compressor oil. Operating Conditions of the Air Conditioner: Engine Speed : Slow Idle Cab Window : Fully Open Cooler Switch : ON Airflow Volume : Maximum Thermo Switch : Maximum Inspection After warm-up operation, carry out gas leak check and performance check. CAUTION: Refrigerant will produce poisonous material if exposed to heat of 1000 ° C (1800 ° F) or more. Never bring refrigerant close to a fire. 1. Check the air conditioner for gas leaks by using a leak tester. Perform checking under well-ventilated conditions.
Thoroughly wipe off dust from the charge hose connections of the compressor. Pay special attention to check the line connections. If any gas leaks are found, retighten the line connections. 2. Performance Check Carry out performance check of the air conditioner after checking each air conditioner component. Check each component for abnormalities. Carry out ON-OFF check of the compressor clutch. Check compressor fan belt tension. Check coolant level in the radiator. Operate the air conditioner and check the performance. Leak Tester W115-02-10-013 Retighten Line Connection W115-02-10-014 T5-4-114