Komatsu — Pump Pressure Control

Automatic Lubrication System - Section 42 OM4214 Page 42-6 LUBRICANT PUMP Pump Housing Oil Level The pump housing must be filled to the proper level with SAE 10W-30 motor oil. Oil level should be checked at 1,000 hour intervals. To add oil, remove oil level plug (4, Figure 42-5) and fill housing to the bottom of plug hole. Pump Pressure Control High pressure hydraulic fluid from the truck steering system is reduced by the pressure reducing valve located on the manifold on top of the pump motor. This pressure can be read if pipe plug (3) is removed, and a gauge is installed on the manifold. FIGURE 42-5. PUMP CONTROLS 1. Pump Pressure Control 2. Override Switch 3. Pipe Plug 4.

Oil Level Plug 5. Flow Control Valve