Komatsu — 3.7.1 EMERGENCY ENGINE SHUTDOWN SWITCHES

OPERATION 3.7 MACHINERY HOUSE 3.7.1 EMERGENCY ENGINE SHUTDOWN SWITCHES Legend for illustration Z26267 (1) Pulling chains for emergency shut down from ground man (special equip- ment). When one of the chains (1) is being pulled down for emergency shut down of both engines, the Operator will be informed by the following message, displayed on the VHMS monitor:

" # Engine shut down has been actuated from ground man" (2) Emergency engine shutdown switch (S33A) on radiator door (3) Emergency engine shutdown switch (S33B) at the main control valves (4) Emergency engine shutdown switch (S33C) in pump compartment on cen- ter post (5) Emergency engine shutdown switch (S33D) at the counterweight (A) Push button of emergency shutdown switches (2, 3, 4 and 5) for stopping both engines (6) Counterweight In case of emergency push in the button (A) to stop both engines. Never stop the engines from a full load except in case of emergency.

If a hot engine is shut down without previous idling period of three to five minutes, the temperature in certain engine parts rising sharply after the cooling sys- tem ceases to function. The resulting thermal stress, especially in the turbochargers, may cause serious dam- age. For releasing button (A) turn it to the right, the button returns to normal position. NOTICE In order to reset the emergency shutdown circuit, set the main key switch at the control panel in the operator's cab to -OFF- position and then to -ON- position. The engines can then be started in the normal way. The engines can not be started with button (A) in depressed position.

When one of the shutdown switches (2 - 5) is activated, the VHMS monitor informs the Operator by a correspond- ing message. 141 WARNING WARNING