OPERATION 3.7 MACHINERY HOUSE 3.7.2 SAFETY SWITCH FOR MAINTENANCE Legend for illustration Z26267 (7) Front door (8) Access door to the oil level gauge of the front engine (9) Access door to the pump compartment (10) Center floor door (11) Maintenance safety switch for start prevention of the engines (12) Rotary switch Switch positions: -0- Engine start blocked -1- Normal operation (13) Securing flap for rotary switch in -0- position (14) Holes for attaching padlocks Before beginning any maintenance operation set the rotary switch (12) to -0- position to prevent starting of the engines during maintenance.
Fold up flap (13) and secure this posi- tion by inserting a padlock into the holes (14) of flap (13) and safety switch (11). Up to ten padlocks can be attached. (15) Light switch (16) Plug socket 24V DC Make sure that all machinery house doors are securely closed before starting the engines. 143 WARNING WARNING CAUTION CAUTION