Komatsu — 3.8.2 SWITCH BOARD (X2) IN CAB BASE

OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE 3.8.2 SWITCH BOARD (X2) IN CAB BASE Legend for illustration Z26323 Switches (S27) Emergency By-pass switch for the shutdown f unction of the PLC (E6). Switch positions: 1 - Normal operating position 2 - By-pass position If an automatic shutdown is initiated by Shovel systems , with a dangerous situation for man or machine, which needs the Shovel to be operable to over-come the dangerous situation, actuate this switch to override the shutdown function of the system and to enable a restart of the Die- sel engine. This switch can not override engine initiated shutdowns. NOTICE As soon as the immediate situation of danger is over, shutdown the unit.

Correct the fault that caused the shut down and re-set the Emergency By-pass switch (S27). (S41.1) Switch for constant speed adjustment of engine 1 to 1800 RPM (rated speed) for testing purposes (S41.2) Switch for constant speed adjustment of engine 2 to 1800 RPM (rated speed) for testing purposes (S97) Switch for upload of new program to VHMS controller (E46), refer to VHMS Service Manual for more informa- tion. 149