OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE Legend for illustration Z26323 Service Indicator Lights (H63) Electronic pump control module (RC4) active and program information (H138) This light pulses if there is a failure in the electronic pump control module (RC4) (H94.1) Engine 1 STOP lamp red. This lamp flashes out fault codes of the QUAN- TUM electronic engine control system. See heading -Checking active diagnostic fault codes- for more information. (H94.2) Engine 2 STOP lamp red. This lamp flashes out fault codes of the QUAN- TUM electronic engine control system. See heading -Checking active diagnostic fault codes- for more information. (H95.1) Engine 1 WARNING lamp yellow.
This lamp flashes out fault codes of the CENSE electronic engine monitoring system. (H95.2) Engine 2 WARNING lamp yellow. This lamp flashes out fault codes of the CENSE electronic engine monitoring system. (H96.1) Engine 1 FLUID lamp white. The engine PROTECTION system will illumi- nate the FLUID lamp when an abnormal condition occurs (H96.2) Engine 2 FLUID lamp white. The engine PROTECTION system will illumi- nate the FLUID lamp when an abnormal condition occurs (H143.1) Monitoring light of the automatic engine oil supply system -Reserve- for engine 1 Steady light: oil is pumped from engine oil pan to reserve oil tank. Regular blinking: oil is pumped from reserve oil tank to engine oil pan.
Irregular blinking: oil is pumped in both directions, oil level in engine oil pan is correct. (H143.2) Monitoring light of the automatic engine oil supply system -Reserve- for engine 2 NOTICE If the indicator lights (H143.1/H143.2) are off with the engines running, there is a failure in the reserve system. Have the reserve systems checked and repaired through authorized service personnel. Other Components (X53.1) Connector for Modular Mining System (MMS) service processor (Option) (X27B) Connector for program upload to the VHMS controller (X30) Plug socket 24 Volt (H1-1) Hour meter engine running (H29) Hour meter traveling operation 151