Komatsu — 3.8.2 SWITCH BOARD (X2) IN CAB BASE

OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE Emergency Indication of Operating Conditions The VHMS system is equipped with an emergency indication via LED’s on the Programmable Logic Controller PLC (E6), illust. Z26324. In case of a malfunction of the monitor in the operator’s cab, the LED’s in the columns (A8/A14) of the PLC indicating failures in vital operating systems of the Shovel. The following faults are indicated: REMARK The location of the numbered LED’s on the PLC may differ from that shown in the illustration. 155 Fault: LED No.: The VHMS system is by-passed (By-pass switch S27 actuated) H30 Start of both engines blocked, resp.

engine shut down, due to closed main shut-off (gate) valve hydraulic tank H37 Faulty monitor channel for hydraulic oil temperature H38 Strainer oil cooler clogged H74 Faulty monitor channel engine speed H112 Emergency shut down switch actuated H116 Engine shutdown from ground man (if so equipped) H135 Operator warning system actuated from ground man (if so equipped) H137 VHMS Controller trouble H151 VHMS Display trouble H152