OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE High Pressure Filter "HPF" Identification Codes of LED H31 The LED ”H31”, illust. Z26324, monitors all six high pressure fil- ters. If a failure condition of a high pressure filter occurs, the LED ”H31” will begin flashing out a diagnostic code for identification of the concerned filter. If more than one filter send a failure signal at the same time, the LED will always show the diagnostic code of that filter with the lowest number. High Pressure Filter "HPF" number: Example: Identification Code for High Pressure Filter #4 :
When the differential pressure switch of high pressure filter #4 sends the signal ”Filter restricted”, the LED H31 will flash four times at regular intervals of 0.5 seconds and then after two sec- onds pause time will start again flashing four times at regular intervals of 0.5 seconds and so on. The number of the four 0.5 seconds interval flashing groups cor- responds to the number of the high pressure filters.
157 Code HPF #1 1 1 1 1 1 Code HPF #2 0.5s 2s 1 2 1 2 1 2 1 Code HPF #3 0.5s 0.5s 0.5s 2s 1 2 3 1 2 3 1 1 Code HPF #4 0.5s 0.5s 0.5s 0.5s 0.5s 2s 1 2 3 4 1 2 3 4 1 Code HPF #5 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 2s 1 2 3 4 5 1 2 3 4 1 4 Code HPF #6 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 2s 1 2 3 4 5 6 1 2 3 1 2 3 4 5 6 1 2 3 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 2s