Komatsu — 3.8.2 SWITCH BOARD (X2) IN CAB BASE

OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE High Pressure Filter "HPF" Identification Codes of LED H31 The LED ”H31”, illust. Z26324, monitors all six high pressure fil- ters. If a failure condition of a high pressure filter occurs, the LED ”H31” will begin flashing out a diagnostic code for identification of the concerned filter. If more than one filter send a failure signal at the same time, the LED will always show the diagnostic code of that filter with the lowest number. High Pressure Filter "HPF" number: Example: Identification Code for High Pressure Filter #4 :

When the differential pressure switch of high pressure filter #4 sends the signal ”Filter restricted”, the LED H31 will flash four times at regular intervals of 0.5 seconds and then after two sec- onds pause time will start again flashing four times at regular intervals of 0.5 seconds and so on. The number of the four 0.5 seconds interval flashing groups cor- responds to the number of the high pressure filters.

157 Code HPF #1 1 1 1 1 1 Code HPF #2 0.5s 2s 1 2 1 2 1 2 1 Code HPF #3 0.5s 0.5s 0.5s 2s 1 2 3 1 2 3 1 1 Code HPF #4 0.5s 0.5s 0.5s 0.5s 0.5s 2s 1 2 3 4 1 2 3 4 1 Code HPF #5 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 2s 1 2 3 4 5 1 2 3 4 1 4 Code HPF #6 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 2s 1 2 3 4 5 6 1 2 3 1 2 3 4 5 6 1 2 3 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 2s