OPERATION 3.9 PREHEATING SYSTEMS FOR OIL, COOLANT AND BATTERIES Hydraulic Oil and PTO Gear Oil Heating Junction Box for Hydraulic Oil Heating and Location of Heat- ers and Thermostats, illustration Z 21755 (1) Junction box for hydraulic oil heating, this box is located in the cab base (2) Switch, hydraulic oil heating ON/OFF. (3) Warning light red, heating system failure, (4) Indicator light green, hydraulic oil heating ON.
(5) Immersion heaters installed in the suction oil reser- voir (6) Immersion heaters installed in the main oil reservoir (7) Immersion heaters installed in the PTO’s (pump dis- tributor gears) (8) Thermostats installed in the main oil reservoir, suc- tion oil reservoir and in the PTO’s (pump distributor gears) (9) Adapter flange for heater element (10) Heater plates for batteries 167