OPERATION 3.11 STARTING THE ENGINES Before starting read the Engine Operation Manual. Observe the instructions for starting the Engine. NOTICE After repairs on the Diesel engines or starter motors, make sure that the ground cables are correctly con- nected before starting the engines. Loose or missing ground cables can cause fire, serious injury or death. Start the engines from the operator’s seat only. Never attempt to start the engine by shorting across starter ter- minals. This can cause fire, serious injury or death. Before each starting make sure that all controls are in neutral position. Be sure to sound the signal horn before starting to make your intention clear.
Before starting the engines and again before starting work, pay attention to the hydraulic oil temperature. Refer to para- graph "Hydraulic Oil Warm-up" in this section. Legend for illustration Z26336 (1) Key operated main switch (2) High level alarm: Automatic engine shutdown . The high level alarm (2) will sound approximately 10 seconds before an auto- matic engine shutdown occurs and will continue to sound during the 10 second period. At the same time a blinking message *SHUTDOWN* will be displayed on the health monitor. Use the time period to move the machine to a safe place and lower the attachment to the ground. Inform service about the shutdown condition.
(3) Health monitor (4) Engine speed selector switch Low idle - High idle (5) Signal horn button (6) Rotary switch - rear engine 1 start (7) Rotary switch - rear engine 1 stop (8) Rotary switch - front engine 2 start (9) Rotary switch -front engine 2 stop (10) Strike button - emergency engine shutdown and cut out of pilot control system (11) Lock lever (12) Acoustic warning signal 175 WARNING WARNING CAUTION CAUTION