Komatsu — 4.9.2 TRAVEL GEARS, MOTOR ADAPTER HOUSINGS AND FINAL DRIVES CHECK OIL LEVELS

MAINTENANCE 4.9 EVERY 50 OPERATING HOURS OR WEEKLY TRAVEL GEARS, MOTOR ADAPTER HOUSINGS AND FINAL DRIVES - CHECK BREATHER FILTERS Legend for illustration Z25243 (11) Connector on travel gear box for breather filter (18) (16) Connectors on motor adapter housing for breather filter (19) (18) Breather filters for travel gears (19) Breather filters for motor adapter housings (20) Breather filters for final drives (21) Pilot oil pressure hydraulic lines for releasing the parking brakes Check the six breather filters(18, 19 and 20), located inside the center frame, for restriction. If necessary, remove breather filters, blow out with compressed air from inside to outside and reinstall. 319