MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Check tightening torque of the counterweight mounting bolts, illustration Z 21778A Reference No.: Qty. (3) Mounting bolts 20 * SW = Wrench size Re-tighten mounting bolts to their correct torque and replace missing or damaged bolts.
Guideline for transportation and lifting of the counterweight illustration Z 21778A (1) A1 and A2 fastening points for vertical transport and for raising up of the counterweight with two symmetrical ropes (2) A1, A2 and A3 fastening points for horizontal transport and for loading of the counterweight with three symmetrical ropes The chambers of the counterweight are filled with a mixture of concrete, granulated ore and steel pellets. This mixture can create explosive gases which will accumulate in the chambers of the counterweight.
Before any welding, flame- cutting, grinding or drilling procedures are carried out on the counterweight it is vital to expel these gases from the coun- terweight chambers. Failure to properly expel the gases from the counterweight chambers can result in an explosion with serious personal injury or death. Follow the instructions given in PARTS & SERVICE NEWS No. AH04518 for expelling the gases from the counterweight chambers. 389 Bolt size mm Grade SW * mm Tightening torque Nm M48 10.9 75 7500 WARNING WARNING