Komatsu — 4.14.1 SWING GEARS, BRAKE HOUSINGS AND MOTOR ADAPTER HOUSINGS - CHANGE OIL

MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR Swing Gears - Change Oil (continued) 6. After short operating period check oil level and housings for leaks. Brake Housing - Change Oil 1. Remove level gauge (8), illustration Z26450, drain plug (9) and breather filter (7). Drain the oil into a receptacle of approx. 5 liter capacity. 2. Clean breather filter (7) with compressed air from inside to outside and re-install. 3. Install drain plug (9) and fill-up engine oil SAE 10 or hydraulic oil HLP 22 or HLP 32 through filler opening up to the lower mark on level gauge (8), see illustration Z26332 on next page for correct oil level indication.

DO NOT overfill the brake housing, otherwise the brake could be damaged due to over- heating. 4. After short operating period check oil level and housing for leaks. Motor Adapter Housing - Change Oil 1. Remove level gauge (6) and drain plug (5). Drain the oil into a receptacle of approx. 5 liter capacity. 2. Install drain plug (5) and fill-up engine oil SAE 10 or hydraulic oil HLP 22 or HLP 32 through filler opening up to the MAX mark on level gauge (6) see illustration Z26332 on next page for correct oil level indication. 3. After short operating period check oil level and housing for leaks. 457