OPERATION 3.3 OPERATOR’S CAB - CONTROLS EURO Control Pattern Legend for illustration (Z 22463) (1) Control lever for stick and swing machinery (2) Control lever for boom and bucket (3) Toggle switch for engine speed selection Low idle – High idle (4) Push button for Truck counter number 1 (TR1) For counting loaded trucks press this button. The total number of trucks loaded is shown on the VHMS monitor field TR1, refer to page 91 for more informa- tion. A second truck counter switch is located on the control panel, refer to page 81 for more information. NOTICE The push button (4) has a second function.
When the Vehicle Health Monitoring System is switched to the PM CLINIC group within the SERVICE MENU, selected PM CLINIC data can be frozen by pushing button (4). Frozen data can then be stored in the PM CLINIC MEMORY. For more information refer to the SERVICE MANUAL VHMS-System. (5) Signal horn button (6) Travel control pedal, left track forward - reverse (7) Travel control pedal, right track forward - reverse (8) Swing brake pedal For more information See "WORKING WITH THE ATTACH- MENT" on page 194. 73