Komatsu — 3.3.3 OPERATOR’S CONSOLE

OPERATION 3.3 OPERATOR’S CAB - CONTROLS Switch Board (continued) Legend for illustration Z26319 (8) WARNING lamp (Yellow) of front engine 2. This lamp is used to monitor engine out-of-range condi- tion, in case the VHMS Monitor fails to function. When this lamp illuminates, the engine can still be operated until end of shift, but it can lose some sys- tem features which sometimes results in power loss (derate condition). Inform Service about the engine problem. (9) STOP lamp (Red) of front engine 2. This lamp is used to monitor engine out-of-range condition, in case the VHMS Monitor fails to function. When this lamp illuminates, stop the engine operation in a safe manner immediately.

The engine monitoring system CENSE or the electronic control module ECM will initiate automatic engine shutdown due to serious engine problem. Inform Service about the engine failure. (10) Rotary switch FRONT Engine 2 START (11) Rotary switch FRONT Engine 2 STOP (12) Switch for warning beacon on cab roof (13) Switch for interior illumination (14) Switch for main working lights (15) Toggle switch, swing parking brake 0 - Parking brake released - UP 1 - Parking brake applied - DOWN. The parking brake should only be applied with superstructure at complete standstill, except in case of emergency. Refer to page 191 for more information. (16) Enable switch for hydraulic service arm operation.

Set this switch to ON position -1- before lowering the service arm. With this switch in ON position, the pilot control system is made inoperative and the hydraulic swing brake is applied. After completion of replenishment procedure, swing back the service arm to its home position and set switch (16) to OFF position -0-. (17) Switch, manual actuation of central lubrication sys- tem 83 CAUTION CAUTION