Komatsu — 3.3.3 OPERATOR’S CONSOLE

OPERATION 3.3 OPERATOR’S CAB - CONTROLS Switch Board (continued) Legend for illustration Z26319 (18) Switch, windshield washer (19) Switch, mirror heating (20) Switch, cab ventilation blower. Blower runs with low speed, even with switch in -0- position. (Cab pressuriz- ing prevents ingress of dust). (21) Switch, manual actuation of swing ring gear pinion lubrication system (22) Switch for upper and lower windshield wiper 0 - Off 1 - Interval stage 2 - Slow stage 3 - Fast stage (23) Switch for Truck counter number 2 (TR2). For counting loaded trucks rotate this switch. The total number of trucks loaded is shown on the VHMS monitor field TR2, refer to page 90 for more information.

The push button for Truck counter number 1 (TR1) is located on the RH control lever. (24) Acoustic warning signal This signal sounds for approximately 1 second when a fault message appears on the VHMS monitor. In case of too low hydraulic oil level this signal sounds continuously. Shut down the Shovel, locate and correct the cause immediately. Fill up hydraulic oil to the correct level. For the correct checking procedure "CHECKS BEFORE START- ING THE ENGINES" on page 168. 85 CAUTION CAUTION