Komatsu — OTHER TROUBLE

. OPERATION TROUBLESHOOTING OTHER TROUBLE 3 - 184 ELECTRICAL SYSTEM ( ) : Always contact your Komatsu distributor when dealing with these items. In cases of problems or causes which are not listed below, contact your Komatsu distributor for repairs.

Problem Main causes Remedy Lamp does not glow brightly even when the engine runs at high speed ( Check,repair loose terminals, disconnections) Adjust alternator belt tension For details, see EVERY 250 HOURS SERVICE Lamp flickers while engine is running Charge lamp does not go out even when engine is running Defective alternator Defective wiring ( Replace) ( Check, repair) Abnormal noise is generated from alternator Defective alternator ( Replace) Starting motor does not turn when starting switch is turned to ON Defective wiring Insufficient battery charge Safety switch out of adjust ( Check, repair) Charge ( Adjust safety switch) Pinion of starting motor keeps going in and out Insufficient battery charge Charge Starting motor turns engine sluggishly Insufficient battery charge Defective starting motor Charge ( Replace) Starting motor disengages before engine starts Defective wiring Insufficient battery charge ( Check, repair) Charge Automatic pre-heating is not actuated Defective wiring Defective heater relay Defective engine controller ( Check, repair) ( Replace) ( Check, replace) Outside of electrical heater in not worm when touched by hand Defective wiring Disconnection in electrical intake air heater Defective operation of heater relay ( Check, repair) ( Replace) ( Check, repair heater relay) Air conditioner does not work properly Blown fuse Insufficient battery charge Defective air conditioner switch Defective blower switch Defective compressor ( Check, repair) Charge ( Replace air conditioner switch) ( Replace blower switch) ( Replace)