SYSTEM / Control System Travel HP Mode Control Purpose: Increases the engine speed and travels faster during travel single operation. ZX200-3 class, ZX225US-3 class, ZX225USR-3 class, ZX240-3 class Operation: 1. When the travel mode switch is in fast idle and all the following conditions exist, MC sends the signals equivalent to the target engine speed to ECM by using CAN communication. 2. ECM increases the engine speed by 200 min -1 (ZX240-3 class: 100 min -1 ) from the speed set by the engine control dial and travels faster. Condition: 1. Engine Control Dial: Set the engine speed in the fast idle speed position. 2. Travel Operation: Operated 3. Front Attachment Operation:
Not Operated (When starting traveling) 4. Delivery Pressure of Pumps 1 and 2: Delivery pressure of either pump is high. (Reference: ZX200-3 class, ZX225US-3 class, ZX225USR-3 class, ZX240-3 class: 19 MPa, (195 kgf/cm 2 , 2760 psi) ZX240-3 class: 15 MPa (153 kgf/cm 2 , 2180 psi)) Engine Speed 1800 min -1 Increasing Range of Fast Idle 1750 min -1 Engine Control Dial Position Slow Idle Fast Idle Model Increasing Range of Fast Idle Speed ZX200-3 class ZX225US-3 class ZX225USR-3 class 200 min 1 ZX240-3 class 100 min 1 T2-2-10