SYSTEM / Control System Auto-Warming Up Control Purpose:Automatically warms up the hydraulic system. (similar to the auto choke on automobiles) Operation: 1. For 12 minutes after the engine starts or when hydraulic oil temperature is below 0 , MC sends the signals equivalent to the target engine speed to ECM by using CAN communication according to the signals from key switch and hydraulic oil temperature sensor. 2. ECM increases the engine speed to the auto-warming up speed. IMPORTANT: When adjusting the auto-idle speed, deactivate the auto-warming up control by using Dr. ZX. Wait adjustment until 12 minutes after the engine starts.
Auto-warming up control can be deactivated temporarily by Dr. ZX. Once the key is turned OFF, auto-warming up control is effective again. IMPORTANT: Auto-warming up speed can be adjusted by Dr. ZX. Engine Speed Fast Idle 1400 min -1 Auto-Warming Up Speed Increasing Speed Slow Idle Slow Idle Fast Idle Engine Control Dial Position T2-2-18