hitachi — ENGINE CONTROL

SYSTEM / Control System Attachment Operation Speed Limit Control (Only Machine Equipped with Attachment Parts) Purpose: Decreases the maximum engine speed to the attachment (hydraulic breaker, secondary crusher, primary crusher or vibrating hammer) operating engine speed set by Dr. ZX when the attachment mode is selected. Operation: 1. When the following conditions exist and the attachment is operated, MC sends the signals equivalent to the target engine speed set by Dr. ZX to ECM by using CAN communication. 2. ECM increases engine speed to the attachment operating speed set by Dr. ZX. Engine Speed When all conditions exist, the maximum engine speed is reduced to the speed set by Dr. ZX.

Engine Control Dial Position Slow Idle Fast Idle Conditions: Dr. ZX: Resets the maximum engine speed to a slower ( ) attachment (hydraulic breaker, secondary crusher, primary crusher or vibrating hammer) operating speed in the service mode. Work Mode: Attachment Mode Auxiliary Mode: Attachment mode Attachment selected by using the monitor unit is set ( ) by Dr. ZX T2-2-26