hitachi — PUMP CONTROL

SYSTEM / Control System Pump 1 Flow Rate Limit Control (Only Machine Equipped with Attachment) Purpose: Limits pump 1 flow rate in order to make up for pump flow rate for attachment operation when attachment (mainly a vibrating hammer) is used and pump 2 flow rate is lack. Operation: 1. When the attachment is used with the travel control lever in neutral, MC receives the signals from pressure sensor (auxiliary) (optional). 2. In response to attachment control operation, MC drives the maximum pump 1 flow rate limit control solenoid valve (optional) and controls pump 1 flow rate. NOTE:

The minimum pump swash set-angle on monitor unit for a attachment (hydraulic breaker 1 to 5, secondary crusher 1 to 5, primary crusher 1 to 5 or vibrating hammer 1 to 5) can be set in the service mode of Dr. ZX. T2-2-36