SYSTEM / Control System Pump 2 Flow Rate Limit Control (Only Machine Equipped with Attachment) Purpose: Limits maximum pump 2 flow rate when a attachment (mainly a hydraulic breaker) is used. Operation: 1. When attachment is used, MC receives the signals from pressure sensor (auxiliary) (optional). 2. In response to attachment control operation, MC drives the maximum pump 2 flow rate limit control solenoid valve and reduces maximum pump flow rate. 3. When the auxiliary flow combining solenoid valve stops, pump 2 flow rate can be adjusted finely by the monitor unit. Q Flow Rate Maximum flow rate is reduced. Normal Pump P-Q Curve NOTE:
In proportion to the attachment control operation, maximum pump flow rated is reduced. The minimum pump swash set-angle on monitor unit for a attachment (hydraulic breaker 1 to 5, secondary crusher 1 to 5, primary crusher 1 to 5 or vibrating hammer 1 to 5) can be set in the service mode of Dr. ZX. P Pressure T2-2-38