hitachi — VALVE CONTROL

SYSTEM / Control System Power Digging Control Purpose: Increases digging force by temporarily increasing relief pressure. Operation: 1. For maximum 8 seconds after the power digging switch is turned ON, MC continuously activates solenoid valve unit (SG). 2. Solenoid valve unit (SG) delivers pilot pressure to the main relief valve in control valve and increases relief pressure. (Refer to Control Valve / COMPONENT OPERATION.) T2-2-44