SYSTEM / Control System ZX270-3 class Operation: Slow When the travel mode switch is in the SLOW position, the travel motor swash angle is kept in the maximum angle so that the travel speed is slow. Fast 1. When MC receives the signals from travel pressure sensor, pump 1 and 2 delivery pressure sensors, pump 1 and 2 control pressure sensors under the following conditions with the travel mode switch in the FAST position, MC shifts solenoid valve unit (SI). 2. When solenoid valve unit (SI) is shifted, pilot pressure acts on the travel motor swash angle control valve and reduces the swash angle to the minimum, so that the travel speed increases. Condition: Travel Pressure Sensor:
Outputting signal Front Attachment Pressure Sensor: OFF Pump 1, 2 Delivery Pressure Sensors: Delivery pressure of either pump is low. (Reference: 24 MPa (245 kgf/cm 2 , 3490 psi) or less) Pumps 1, 2 Control Pressure Sensors: Both pump control pressures are high. (Reference: 2.2 MPa (22 kgf/cm 2 , 320psi) or more) NOTE: When the machine is traveling in the fast speed and even if the front attachment is operated (the front attachment pressure sensor: ON), the travel mode is kept in the fast speed. When one side track is raise off the ground and is rotated, the one side pump control pressure does not increase, so that the raised track does not rotate at fast speed. T2-2-54