SYSTEM / Control System NPK Breaker Control (Optional) IMPORTANT: NPK breaker is set at breaker 2 of attachment mode in monitor unit when the machine is carried out. When breaker 3 to 5 is used, set the setting by using Dr. ZX. Operation: 1. When selecting breaker 2 in monitor unit, MC drives the selector valve control solenoid valve. 2. Pressure oil from the pilot pump flows through the selector valve control solenoid valve, shifts the selector valve, and the return circuit in breaker is connected to the hydraulic oil tank. 3. At the same time, MC drives the accumulator control solenoid valve. 4.
Pressure oil from the pilot pump flows the accumulator control solenoid valve and shifts the accumulator control valve. 5. The accumulator is connected to either high pressure side or low pressure side in breaker and reduces shock of oil pressure while using the breaker. 6. When the maximum pump 2 flow rate limit control solenoid valve is driven in the monitor unit, pump 2 flow rate can be adjusted finely. T1V5-05-01-112 T2-2-58