COMPONENT OPERATION / Pump Device SOLENOID VALVE The torque control solenoid valve and maximum pump 2 flow rate limit control solenoid valve are provided on the pump 2 regulator. The torque control solenoid valve supplies torque control pressure Pps to both the pump 1 and pump 2 regulators and the pump delivery flow rate decreases. The maximum pump 2 flow rate limit control solenoid valve reduces the pump control pressure to the pump 2 regulator so that the upper limit pump delivery flow rate is limited. Operation 1. When in neutral, port P is connected to the output port through the notch on spool. 2.
When the current flows to the solenoid from the main controller (MC), the solenoid is magnetized and pushes the piston. 3. The piston pushes the spool so that the output port is connected to port T through the notch on spool. 4. Thereby, pressure at the output port begins to decrease. 5. As for the notch, spool diameter (B) is larger than spool diameter (A). 6. Accordingly, when pressure at the output port begins to decrease, the spool is move toward the right side because of the force as Fsol + P1 Ч B + S1 > P1 Ч A + S2. 7. When pressure at the output port disappears and when Fsol + P1 Ч B + S1 becomes equal to P1 Ч A + S2, the spool stops moving. P1 : Pressure at the output port A and B:
Pressure receiving area on the spool S1 : Spring 1 force (pushing the spool toward the right side) S2 : Spring 2 force (pushing the spool toward the left side) Fsol: Force of the solenoid T3-1-22