hitachi — AUXILIARY FLOW COMBINER VALVE AND BYPASS SHUT-OUT VALVE

COMPONENT OPERTATION / Control Valve AUXILIARY FLOW COMBINER VALVE AND BYPASS SHUT-OUT VALVE The auxiliary flow combiner valve and the bypass shut-out valve are provided in the 5-spool section circuit and the rear of 4-spool section circuit respectively. These valve functions differ depending on whether only the front attachment is single-operated or combined- operated. During Single Operation When the front attachment is single operated, pressure oil from both pumps 1 and 2 is combined. Therefore, operating speed of front attachment increases. 1.

When the front attachment is single operated, front attachemt pilot pressure acts to ports SM and SJ and the spools in auxiliary flow combiner valve and bypass shut-out valve are shifted. 2. When the spool in bypass shut-put valve is shifted, the neutral circuit in 4-spool section is blocked. 3. At this time, as the spool in auxiliary flow combiner valve is shifted, pressure oil in 4-spool section (pump 1) flows to the auxiliary spool through the auxiliary flow combining valve. 4. Consequently, pressure oil in pumps 1 and 2 is combined so that operating speed of front attachment increases.

Auxiliary Flow Combiner Valve To Auxiliary Spool SM Front Attachment Pilot Pressure Pressure Oil from Pump 1 Check Valve Spool T1V1-03-03-066 To Hydraulic Oil Tank Bypass Shut-Out Valve NOTE: The external shuttle valve is installed to the machine equipped with the optional auxiliary flow combining system. During front attachment operation, front attachment pilot pressure shifts the pump 1 flow rate control valve in signal control valve through the external shuttle valve. Therefore, swash angle of pump 1 becomes maximum and delivery flow rate increases.

(Refer to “Pump Device” and “Signal Control Valve”/ COMPONENT OPERATION.) Neutral Circuit in 4-Spool Section Front Attachment Pilot Pressure SJ T1V1-03-03-068 To Hydraulic Oil Tank Spool T3-3-44